Line 22: | Line 22: | ||
The easiest way to use this is to generate your Gcode elsewhere (using Cura or other slicing software), copy the files to an SD card, and print via the printer' | The easiest way to use this is to generate your Gcode elsewhere (using Cura or other slicing software), copy the files to an SD card, and print via the printer' | ||
- | See the [[Monoprice MP Select Mini 3D Printer]] article for operation information- they're similar. | + | Filament-wise, we've used PLA approximately 99% of the time on this one. We have done a little PETG, but never ABS or more exotic filaments |
- | {{tag>[ needs_calibration | + | See the [[Monoprice MP Select Mini]] article for operation information- they' |
+ | |||
+ | Modifications: | ||
+ | * The hotend was upgraded to a Micro-Swiss all-metal hotend. The nozzle is " | ||
+ | * The extruder cooling fan failed and was replaced. However, the replacement is a 12V and apparently all the high-voltage stuff on this is 24V? The replacement is working, but I expect it to eventually fail. Need to get 24V fans sooner than later. | ||
+ | |||
+ | Slicer configuration: | ||
+ | * For the most part, Cura's defaults are fine- set the size to 200x200x200 (or use their canned Prusa i3 profile) | ||
+ | | ||
+ | | ||
+ | * Retraction distance: .6mm | ||
+ | * Bed Temperature: | ||
+ | |||
+ | {{tag>[ needs_calibration, needs_minor_repair, |