User Tools

Site Tools


duplicator_i3_plus_3d_printer

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
duplicator_i3_plus_3d_printer [2018/11/30 19:28] sdh7duplicator_i3_plus_3d_printer [2022/10/26 11:10] (current) – update with current condition. sdh7
Line 9: Line 9:
 ^Serial| UNKNOWN| ^Serial| UNKNOWN|
 ^Arrival Date| UNKNOWN| ^Arrival Date| UNKNOWN|
-^Working| Yes|+^Working| No|
 ^Contact| Sam Harmon| ^Contact| Sam Harmon|
  
-Current Status: Fully Functional+Current Status: Broken. Needs major refurb: 
 +  *Leveling issues 
 +  *alignment issues 
 +  *Adhesion issues 
 +  *X-axis has a weird "lump" sometimes causing prints any larger then a 20mm calibration cube to be offset per-layer. 
 +  *Y-axis limit switch was somehow damaged?
  
-Current workhorse printer at the space.+<del>Current workhorse printer at the space.</del>
  
 Print area: 200x200x200 mm (approx) Print area: 200x200x200 mm (approx)
  
-Could maybe use a bed leveling.+
  
 The easiest way to use this is to generate your Gcode elsewhere (using Cura or other slicing software), copy the files to an SD card, and print via the printer's front panel. The easiest way to use this is to generate your Gcode elsewhere (using Cura or other slicing software), copy the files to an SD card, and print via the printer's front panel.
Line 28: Line 33:
 Modifications: Modifications:
   * The hotend was upgraded to a Micro-Swiss all-metal hotend. The nozzle is "plated brass", so extended amounts of glow in the dark filament may not be the best idea until we get an all-stainless or something else.   * The hotend was upgraded to a Micro-Swiss all-metal hotend. The nozzle is "plated brass", so extended amounts of glow in the dark filament may not be the best idea until we get an all-stainless or something else.
-  * The extruder cooling fan failed and was replaced. However, the replacement is a 12V and apparently all the high-voltage stuff on this is 24V? The replacement is working, but I expect it to eventually fail. Need to get 24V fans sooner than later.+  * The extruder cooling fan has been replaced several times (note: it's a 24 V fan)
  
 Slicer configuration: Slicer configuration:
Line 34: Line 39:
  *Nozzle diameter: 0.4 mm (this is actually the default, but noting it for now in case it changes in the future)  *Nozzle diameter: 0.4 mm (this is actually the default, but noting it for now in case it changes in the future)
  *Enable Retraction  *Enable Retraction
-  * Retraction distance: .6mm+  * Retraction distance: .6mm (this is important with the all-metal hotend)
  * Bed Temperature: 45  * Bed Temperature: 45
  
 {{tag>[ needs_calibration, needs_minor_repair,needs_details]}} {{tag>[ needs_calibration, needs_minor_repair,needs_details]}}
duplicator_i3_plus_3d_printer.txt · Last modified: 2022/10/26 11:10 by sdh7

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki